8460236049 | [email protected]

VFD Panel

VFD (Variable Frequency Drive) Control Panel Specification

A VFD Panel (Variable Frequency Drive Panel) is used to control motor speed by adjusting the frequency and voltage of the power supply. It enhances energy efficiency, reduces mechanical stress on motors, and provides better process control in industries such as HVAC, manufacturing, water treatment, and oil & gas.

1. General Specifications:
- Standards Compliance:
- IEC 61439 / IEC 61800 / IS 8623 / IS 13947 (For switchgear and control gear)
- NEMA / ANSI / UL 508A (As per client requirements)
- Construction Type:
- Floor-mounted / Wall-mounted / Free-standing
- Fixed type or Modular (Compartmentalized) design
- Enclosure Material:
- Mild Steel (MS), Stainless Steel (SS), or Aluminum
- Powder-coated / Painted for corrosion protection
- Degree of Protection (IP Rating):
- IP42 / IP54 / IP55 (For indoor applications)
- IP65 / IP66 (For outdoor applications)
- Cooling System:
- Natural air ventilation / Forced cooling with fans / Heat exchanger
- Cable Entry:
- Top / Bottom cable entry

2. Electrical Specifications:
- Input Voltage Range:
- 220V / 380V / 415V / 480V / 690V AC, 3-Phase, 50/60 Hz
- Output Voltage:
- 0 to Rated Input Voltage (Controlled by VFD)
- Power Rating:
- 0.5 HP to 1000 HP (0.37 kW to 750 kW)
- Busbar Material:
- Copper / Aluminum
- Short Circuit Withstand Capacity:
- 25kA / 50kA / 65kA for 1 sec
- Harmonic Mitigation (Optional):
- Line Reactors / Harmonic Filters / Isolation Transformers

3. Components & Features:
- Main Incomer:
- MCCB (Molded Case Circuit Breaker) / SFU (Switch Fuse Unit) / MCB (Miniature Circuit Breaker)
- Contactor for Bypass Operation (Optional)
- Variable Frequency Drive (VFD):
- Top brands like Siemens, ABB, Schneider, Danfoss, Delta, Yaskawa, etc.
- Control Modes: V/F (Voltage/Frequency), Vector Control, Torque Control
- Built-in Protections: Overvoltage, Overcurrent, Short Circuit, Ground Fault, Thermal Overload
- Control & Monitoring:
- Digital Display (HMI) for speed, voltage, and frequency monitoring
- Local / Remote Control Mode (Manual / Auto Selection)
- PLC / SCADA Integration (Optional)
- RS485 / Modbus / Ethernet Communication (Optional)
- Protection & Safety Features:
- Phase Loss / Phase Reversal Protection
- Overload, Short Circuit, and Earth Fault Protection
- Emergency Stop Button
- IP Rated Ventilation System for Cooling

4. Optional Features:
- Bypass System: Manual / Automatic Bypass Contactor for emergency operation
- Soft Starter Integration for hybrid motor control
- Multi-VFD Control Panel for operating multiple motors from a single panel
- IoT-Enabled Remote Monitoring & Control (Industry 4.0 Ready)

Would you like specifications for a specific type of VFD panel, such as pump VFD panels, HVAC VFD panels, or multi-motor VFD panels?

 